Hydraulic & BOP Control Fluid Concentrates

Waterbased hydraulic fluid specifically formulated for use in high-pressure open / vent to sea Blow Out Preventer (BOP) control systems.






Description

RXSOL-16-3764-210 is a field proven, dilutable, waterbased hydraulic fluid specifically formulated for use in high-pressure open / vent to sea Blow Out Preventer (BOP) control systems. The fluid prevents valves from sticking even after long static periods and improves system life under slow moving high load conditions. RXSOL-16-3764-210 is capable of use at 1% dilution in fresh potable water (hardness ≤125ppm) and standard
 

Application:

Approvals
RXSOL-16-3764-210 meets acceptance requirements of all equipment manufactures (RXSOL) and is a preferred fluid.

 

Dose:

* High dilution ratio (100:1)

Environmental Information
RXSOL maintains worldwide environment and can offer RXSOL-16-3764-210 suitable for use in every Exploration and Production region around the world. The current environmental status of RXSOL-16-3764-210 in your area can be obtained from our environmental specialists.

Storage
RXSOL-16-3764-210 should be stored in dry conditions, ideally out of direct sunlight. Normal storage temperature range is 5 to 40°C.

Material Compatibility
RXSOL-16-3764-210 Series contain performance additives which ensure high levels of compatibility with materials typically used in Blow out Preventer (BOP) control systems. Extensive material compatibility tests have been performed with RXSOL-16-3764-210 Series.

Note:

Key Benefits
* High dilution ratio (100:1)
* High-performance ferrrous and non-ferrous corrosion protection
* Excellent extreme pressure and anit-wear lubrication properties
* High resistance to microbial contamination n Good mixed fluid stability with fresh water and seawater ingress (10%)
* Free Fluid Monitoring programme ensures long service life
* No dye formula meets worldwide environmental acceptance criteria

Additional information

MSDS

Product Name

RXSOL-16-3764-210

Product Type

Hydraulic & BOP Control Fluid Concentrates

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Phone

+91 22 65113333 / 5555 / 9999 / 27611360

Fax

+91 22 2781 1318 :::AOH :0091 9821214367

Email

mail@rxmarine.com

Chemica Name

CAS Number

EC Number

R Phrases*

Symbols Disodium

Ethylene Glycol

107-21-1

 

 

 

Tall Oil amide

Confidential

 

 

 

Sodium N-lauroylsarcosinate

Confidential

 

 

 

*See Section 16

Odour

Mild amine

Appearance

amber

Contact with eyes

May cause discomfort and/or stinging

Contact with skin

May cause itching on prolonged contact

Ingestion

May cause nausea and/or vomiting. Ingestion of 100ml of ethylene glycol has been proved to be fatal.

Contact with skin

Wash with soap and water. Launder contaminated clothing before re-use. If irritation occurs seek medical
attention.

Contact with eyes

Rinse the eye with fresh water for at least 15 minutes. If discomfort persists seek medical attention

Inhalation

In case of symptoms refer for medical treatment. Remove to fresh air.

Suitable extinguishing agents:
Water spray, carbon dioxide, dry powder or foam.
Special hazards caused by the substance, its products of combustion or resulting gases:
Decomposition products include oxides of carbon
Protective equipment:
Self-contained breathing apparatus and full protective clothing required.

Personal Precautions

Gloves and eye protection should be worn when handling the product

Environmental Precautions

Prevent the spillage entering drains and watercourses

Clean Up Actions

Small spillages may be flushed away with a large volume of water. Large spillages should be absorbed using sand, earth or other absorbent material. Place all absorbed waste into suitable containers for subsequent disposal by a licensed contractor.

Handling

Gloves and eye protection should be worn when handling the product

Storage

Store away from foodstuffs and out of direct sunlight.

Personal protective equipment:
General protective and hygienic measures:
Adhere to good laboratory practice (GLP).
Wash hands before breaks and at the end of work.
Protection of hands:
Protective gloves should be worn.
Material of gloves:
We recommend latex, neoprene, nitrile or natural rubber.
Penetration time of glove material:
Penetration time > 8 hours.
Eye protection:
Safety glasses should be worn. Goggles or a face shield are recommended where there is a risk of accidental splashing.
Body protection:
Overalls should be worn when handling the product.

 

Odour

Mild amine

Appearance

amber

pH

9.8 at 100%

Boiling point

100°C

Vapour pressure

2.33 KN.m-2

Stability:
Stable.
Materials to be avoided:
None known
Hazardous reactions:
None known.
Hazardous decomposition products:
None known.

Toxicological information

No experimental data available Inhalation.
Vapours or aerosols may cause irritation of Eyes, Nose and Respiratory tract.

Contact with skin

May cause itching on prolonged contact

Contact with eyes

May cause discomfort and/or stinging

Ingestion

May cause nausea and/or vomiting. Ingestion of 100ml of ethylene glycol has been proved to be fatal.

Ecotoxicity

Product is biodegradable and does not bioaccumulate.

Aquatic toxicity:

This product is of low toxicity.

Product:
The product should be disposed of as hazardous waste, in accordance with local regulations.
Packaging:
Contaminated packaging must be disposed of in the same matter as the product.
Non-contaminated packaging may be recycled. Contact you local service providers for more information.

Land transport ADR/RID (cross border):
Not regulated.
Maritime transport IMDG:
Not regulated.
Air transport ICAO/IATA Class:
Not regulated.

Labelling according to EC guidelines:
The product has been labelled in accordance with EC directives
Code letter and hazard designation of product:
Xn – Harmful
Risk phrases:
R22 – Harmful if swallowed
R36/38 – Irritating to skin and eyes
Safety phrases:
S2 – Keep out of reach of children
S37/39 – Wear suitable gloves and eye/face protection

Text of R and S phrase codes used in this safety data sheet:- R34: Causes burns; R36: Irritating to eyes; R37: Irritating to respiratory system; R41: Risk of serious damage to eyes. The information provided about the product on this Safety Data Sheet has been compiled from knowledge of the individual constituents The data given here is based on current knowledge and experience. This Safety Data Sheet describes the product in terms of safety requirements and does not signify any warranty with regard to the product's properties The data given here only applies when product used for proper application(s). The product is not sold as suitable for other applications – usage in such may cause risks not mentioned in this sheet. Do not use for other application(s) without seeking advice from manufacturer .