Boiler Water Treatment Autotreat

Autotreat is a boiler water conditioner designed for optimum protection of boiler systems when used in conjunction with Oxygen Scavenger Plus. This well known phosphate treatment with new polymer technology. which helps to keep precipitates soft and no adherent for easy removal by blow down.

Description

Boiler Water Treatment AUTOTREAT Boiler Water Treatment Chemical:

Boiler Water Treatment AUTOTREAT Boiler Water Treatment Chemical – Complete Solution for Boiler Protection

Boilers are critical equipment in marine and industrial operations, and maintaining proper water quality is essential for efficient performance and long service life. Poor boiler water treatment can lead to scale formation, corrosion, sludge buildup, and reduced heat transfer efficiency. AUTOTREAT Boiler Water Treatment Chemical is specially formulated to provide complete protection for boiler systems.

Autotreat is a boiler water conditioner designed for optimum protection of ships boiler systems when used in conjunction with Oxygen Scavenger Plus. The product combines well known phosphate treatment with new polymer technology. This ensures that precipitates are kept soft and no adherent for easy removal by blow down. The product should always be used in conjunction with an oxygen scavenger, preferably RXSOL Oxygen Scavenger Plus. Note that this product is formulated for use in conjunction with good quality feed water.






Product Details

Application

Boiler Water Treatment Chemical Autotreat : Autotreat is a multifunctional, liquid boiler water treatment, formulated with alkaline compounds, scale inhibitor, dispersant, and volatile amines for the protection of the feed, boiler and condensate systems.
 

What is Boiler Water Treatment AUTOTREAT Boiler Water Treatment Chemical?

 

Boiler Water Treatment AUTOTREAT is a multi-functional boiler water treatment chemical designed to control alkalinity, corrosion, scale formation, and sludge deposition in boiler systems. Its advanced formulation helps maintain clean boiler internals, ensuring safe and efficient operation.

It is widely used in:

  • Marine boilers

  • Industrial steam boilers

  • Heating systems

  • Auxiliary boilers

  • Closed water circulation systems

Why Boiler Water Treatment is Important?

 

Untreated boiler water can cause:

  • Scale formation that reduces heat transfer

  • Corrosion leading to metal damage and leaks

  • Sludge accumulation causing blockages

  • Fuel wastage due to poor efficiency

  • Boiler downtime and expensive repairs

Using a quality boiler treatment chemical like AUTOTREAT helps avoid these problems.

Dosage & Procedure

The product should preferably be dosed continuously with a Rxsol Boiler Water Treatment Dosing Unit. Alternatively the product can be fed into the feed line by means of a by-pass pot feeder.

Dosage and control

Minimum dosage is 1.2 liters of Autotreat/ton of boiler capacity to reach a P-Alkalinity level of 100 ppm. For an untreated system it is recommended to initially bring the treatment up to a suitable level of 200 ppm p-Alkalinity. The dosage chart given below is for convenience to determine the amount of product required to elevate P-Alkalinity. Note that the table is based on reaching 200 ppm. P-Alkalinity.

 

Sampling and testing

A representative sample of boiler water should be drawn for analysis daily. The sample should always be taken from the same point after blow down, cooled and tested immediately. Follow the Spectrapak Test Kit instructions and log the results. It is important that regular testing is carried out to ensure that treatment levels are correct.
 

Key Benefits of Boiler Water Treatment AUTOTREAT Boiler Water Treatment Chemical

1. Prevents Scale Formation

Boiler Water Treatment AUTOTREAT controls hardness salts and prevents scale buildup inside boiler tubes.

2. Controls Corrosion

Protects boiler metal surfaces against oxygen and acidic corrosion.

3. Maintains Alkalinity

Helps maintain the proper pH and alkalinity level for efficient boiler operation.

4. Reduces Sludge Build-Up

Conditions suspended solids for easy removal during blowdown.

5. Improves Boiler Efficiency

Keeps heat transfer surfaces clean for better fuel economy.

6. Extends Boiler Life

Regular use helps prolong the lifespan of boiler systems.

Technical Specifications

Autotreat is a specialized boiler water conditioner engineered for maximum system protection. It combines proven phosphate treatment with advanced polymer technology. The formulation ensures scale and sludge remain soft and non-adherent. Easier removal through blow down improves operational efficiency. When used with RXSOL Oxygen Scavenger Plus, it provides complete boiler protection.

  • Advanced phosphate–polymer blend for superior conditioning
  • Keeps deposits soft, loose, and easy to remove
  • Enhances efficiency and reduces maintenance costs
  • Works synergistically with RXSOL Oxygen Scavenger Plus for full system protection

TOTAL BOILER PROTECTION
 

Why Choose Boiler Water Treatment AUTOTREAT?

Boiler Water Treatment AUTOTREAT Boiler Water Treatment Chemical provides reliable all-in-one protection against scale, corrosion, and sludge, making it an ideal choice for marine and industrial boiler systems. It improves efficiency, reduces maintenance costs, and ensures safe boiler operation.

Keywords:

AUTOTREAT Boiler Water Treatment Chemical, Boiler Water Treatment Chemical, Marine Boiler Chemical, Industrial Boiler Chemical, Boiler Scale Inhibitor, Boiler Corrosion Inhibitor, Boiler Sludge Conditioner

Notes & Precautions

Applications of Boiler Water Treatment AUTOTREAT

  • Marine boiler water treatment

  • Industrial boiler maintenance

  • Steam generation systems

  • Auxiliary boiler protection

  • Closed-loop heating systems

How to Use Boiler Water Treatment AUTOTREAT Boiler Chemical

  1. Test boiler water parameters.

  2. Dose Boiler Water Treatment AUTOTREAT directly into the boiler feed system.

  3. Maintain recommended alkalinity and pH levels.

  4. Perform regular blowdown to remove sludge.

  5. Monitor water quality for best results.

Dosage depends on boiler capacity and water conditions.

 

  • Liquid boiler water treatment chemical for simplified dosing and handling.
  • Suitable for all boilers, up to 30 Bar pressure.
  • Prevents scaling and corrosion, increasing system life and reliability.
  • Contains volatile amines to neutralize acids occurring in condensate system.
  • Dispersant action suspends sludge and sediment particles for efficient removal by blow down.
  • Suitable for dosing with Rxsol Boiler Water Treatment Dosing Unit.
  • Keeps boiler tube surfaces clean, promoting the best heat transfer conditions, saving energy.
  • Simple testing to determine treatment level.

Generic / Chemical Name

ONE SHOT Boiler Water Treatment Chemicals

Supply Locations

Boiler Water Treatment Marine Boiler Auto Treat Chemicals manufacturer and supplier in India, UAE Oman Nairobi. RXSOL AUTO Treat Boiler Water Treatment Chemicals supplier in Gahala Ruwi Barka Muscat Oman, Fujairah Sharjah Ajman, Abudhabi, Dubai, Mumbai, Surat Hazira, Gandhidham, Kandla, Mundra, Visakhapatnam, Gangavaram, Chennai Ennore, Haldia Kolkata, Paradip, Nairobi Kenya

Industry Applications

Boiler Water Treatment AUTOTREAT Boiler Water Treatment Chemical:

Boiler Water Treatment AUTOTREAT Boiler Water Treatment Chemical – Complete Solution for Boiler Protection

Boilers are critical equipment in marine and industrial operations, and maintaining proper water quality is essential for efficient performance and long service life. Poor boiler water treatment can lead to scale formation, corrosion, sludge buildup, and reduced heat transfer efficiency. AUTOTREAT Boiler Water Treatment Chemical is specially formulated to provide complete protection for boiler systems.

What is Boiler Water Treatment AUTOTREAT Boiler Water Treatment Chemical?

Boiler Water Treatment AUTOTREAT is a multi-functional boiler water treatment chemical designed to control alkalinity, corrosion, scale formation, and sludge deposition in boiler systems. Its advanced formulation helps maintain clean boiler internals, ensuring safe and efficient operation.

It is widely used in:

  • Marine boilers

  • Industrial steam boilers

  • Heating systems

  • Auxiliary boilers

  • Closed water circulation systems

Why Boiler Water Treatment is Important?

Untreated boiler water can cause:

  • Scale formation that reduces heat transfer

  • Corrosion leading to metal damage and leaks

  • Sludge accumulation causing blockages

  • Fuel wastage due to poor efficiency

  • Boiler downtime and expensive repairs

Using a quality boiler treatment chemical like AUTOTREAT helps avoid these problems.

Key Benefits of Boiler Water Treatment AUTOTREAT Boiler Water Treatment Chemical

1. Prevents Scale Formation

Boiler Water Treatment AUTOTREAT controls hardness salts and prevents scale buildup inside boiler tubes.

2. Controls Corrosion

Protects boiler metal surfaces against oxygen and acidic corrosion.

3. Maintains Alkalinity

Helps maintain the proper pH and alkalinity level for efficient boiler operation.

4. Reduces Sludge Build-Up

Conditions suspended solids for easy removal during blowdown.

5. Improves Boiler Efficiency

Keeps heat transfer surfaces clean for better fuel economy.

6. Extends Boiler Life

Regular use helps prolong the lifespan of boiler systems.

Applications of Boiler Water Treatment AUTOTREAT

  • Marine boiler water treatment

  • Industrial boiler maintenance

  • Steam generation systems

  • Auxiliary boiler protection

  • Closed-loop heating systems

How to Use Boiler Water Treatment AUTOTREAT Boiler Chemical

  1. Test boiler water parameters.

  2. Dose Boiler Water Treatment AUTOTREAT directly into the boiler feed system.

  3. Maintain recommended alkalinity and pH levels.

  4. Perform regular blowdown to remove sludge.

  5. Monitor water quality for best results.

Dosage depends on boiler capacity and water conditions.

Why Choose Boiler Water Treatment AUTOTREAT?

Boiler Water Treatment AUTOTREAT Boiler Water Treatment Chemical provides reliable all-in-one protection against scale, corrosion, and sludge, making it an ideal choice for marine and industrial boiler systems. It improves efficiency, reduces maintenance costs, and ensures safe boiler operation.

Keywords:

AUTOTREAT Boiler Water Treatment Chemical, Boiler Water Treatment Chemical, Marine Boiler Chemical, Industrial Boiler Chemical, Boiler Scale Inhibitor, Boiler Corrosion Inhibitor, Boiler Sludge Conditioner



RXSOL Valuable Water Treatment Chemicals and Products
1) Oxygen scavengers, corrosion inhibitors, Alkalinity builders, Scale inhibitors, Antifoams, Sludge conditioning agents, Condensate Treatment Chemicals and Cleaning Chemicals for Steam & Hot Water Boilers.
2) Corrosion & Scale Inhibitors, Biocides & Algaecides, Antifoams, Dispersants & Sludge Conditioners, Flushing and cleaning chemicals for Open Re-circulating Cooling System (Cooling Towers).
3) Corrosion Inhibitors, Biocides, Flushing and cleaning chemicals for Closed Loop Re-circulating Cooling Systems (Chillers)
4) Antiscalants and Cleaning Chemicals for Reverse Osmosis Plants.
5) Corrosion (Red water) inhibitors and Disinfectants for Potable & Domestic Water Pipe Networks
6) Cationic, Anionic and Mixed bed Ion Exchange Resins
7) Organic and Inorganic flocculants & Coagulants for water and waste water
8) Activated Carbon for Potable Water, Waste Water, Chemical and Petrochemical Industries and Oil & Gas. Activated carbon suppliers in UAE, Dubai, Sharjah, Abu Dhabi, Qatar, Saudi Arabia
9) Odour control chemicals for waste water
10) Filtration media .. Sand, Gravel, Anthracite, Birm and others.

Safety Data (MSDS)

Product Name : RXSOL-50-5020-025
Product Type :

BOILER WATER TREATMENT AUTO TREAT

 Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Phone : +91 22 65113333 / 5555 / 9999 / 27611360
Fax : +91 22 2781 1318 :::AOH :0091 9821214367
Email : mail@rxmarine.com , sales@tankcleaner.net/
Website : www.rxmarine.com/ , www.tankcleaner.net/

 Chemica Name  Concentration  CAS Number  EC Number  R Phrases*  Symbols
 Potassium   hydroxide           1-5  1310-58-3 215-181   22-35  C
 Tripotassium phosphate  1-5  7778-58-3 231-907-1 
Proprietory Blend Polymer and Chelating Agent 80-90 --- --- --- ---

*See Section 16

corrosive

Corrosive

Odour Odourless
Appearance Liquid, colour less to yellow, soluble in water
Contact with eyes Corrosive to eyes, Can cause damage to the eyes
Contact with skin Causes burns(R34)
Inhalation No information available but must be considered harmful
Ingestion Harmful if swallowed(R22)

 Contact with skin Remove contaminated clothing immediately and drench affected skin with plenty of water. Then wash withsoap and water. Seek medical advice if necessary
Contact with eyes

If substance has got into eyes, immediately wash out with plenty of water for at least 15minutes
Irrigate eyes thorough lywhilst lifting eyelids               
Obtain immediate medical attention
Continue flushing with water until medical help arrives

 Ingestion Do not induce vomiting
Never give anything by mouth to anunconscious person
Give water or milk to drink
Obtain immediate medical attention
 Inhalation Inhalation is unlikely to occur
Seek medical attention if ill effects occur
 General

In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible)(S45)
When in doubt orsymptoms persist, seek medical attention

-  Non combustible

-  Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions

       

Personal Precautions

Wear protective clothing as persection 8
Environmental Precautions No special precautions are required for this product
Clean Up Actions

Absorb spillageininert material and shovelup
Ventilate the area and wash spill site after material pick-up is complete

Special Precautions  Wear protective clothing as persection 8

 

Handling

Wear protective clothing as persection 8
Eye wash bottles should be available
Avoid contact with skin and eyes(S24/25)

Storage

Keep only in the original container in a cool, well ventilated place(S3/9/49)
Keep container tightly closed(S7)

Exposure Limits

TLV(TWA)2mg/m3(Potassium hydroxide)

Exposure controls

No special precautions are required for this product

Occupational exposure controls

Wear suitable protective clothing,including eye/face protection and gloves(plastic or rubbera recommended)

gloves              goggles             suit              no_smoking

Gloves                 Goggles                    Suit               No_Smoking

Odour Odourless
Appearance Liquid, colour less to yellow, soluble in water
pH 13at 100%concentration
pH9.5 11at 0.2 %concentration
Boiling point &gt 100degreeCat 760mm/Hg
Vapourpressure not known
Vapourdensity not applicable
Freezing point <0degreeCat 760mm/Hg
Soluble in water Completely
Specific gravity (water=1)1.135

-  This article is considered stable under normal conditions
-  Avoid over heating, Keep away from frost
-  In compatible with acid
-  See Section 5

Toxicological information

No experimental data available
Inhalation In halation is unlikely to occur
Contact with skin Prolonged skin or eye contact may cause chemical burns
Contact with eyes Prolonged skin or eye contact may cause chemical burns
Ingestion The ingestion of significant quantities may cause burning sensation
Carcinogenicity No evidence of carcinogenic effects

 

Ecotoxicity May cause acute effects in the aquatic environment
Mobility Completely soluble in water
Persistence and Biodegradability Degrades by hydrolysis
Bioaccumulation Potential Bioaccumulation of the components in this product is insignificant.
Other Adverse Effects No environmental problems are expected when the product is used / handled correctly.
In its intended use, the product will not be released into the environment.
Presents little or no hazard to the aquatic environment

Classification

EUWasteclass: 06.02  

This material and/or its container must be disposed of as hazardous

Disposal considerations

Do not discharge into drains or the environment,dispose to an authorised waste collection point
Disposal should be in accordance with local, state or national legislation

     

 

ProperShippingName: POTASSIUMHYDROXIDE, SOLUTION

UN

ProperShippingName:

UNNo.:

 Potassiumhydroxide, solution

1814

HazardClass:

Road/Rail(ADR/RID)

ProperShippingName:

ADRUNNo.:

ADRHazardClass:

 8PackingGroup:

 Potassiumhydroxide, solution

1814

8

III

ProperShippingName:

IMDG UNNo.:

Revision: 31/12/2008

Potassiumhydroxide, solution

1814

IMDG HazardClass.:

IMDG EmS:

IMDG Labels:

Air(ICAO/IATA)

ProperShippingName:

ICAO UnNo.:

ICAO HazardClass.:

ICAO subrisk:

ICAO Flashpoint:

 8IMDG PackGroup.:

F-A, S-BIMDG subrisk:

8IMDG Flashpoint:

 Potassiumhydroxide, solution

1814

8ICAO PackingGroup.:

N/AICAO Labels:

N/A

 III

N/A

N/A

III

8, CAO

DOT/ CFR(USDepartment ofTransportation

DOTProperShippingName:Potassiumhydroxide, solution

HazardousMaterial:

potassiumhydroxide

HazardClass:

Product RQ (lbs):

DOTLabels:

- For bidden on passenger air craft

 

 

 RiskPhrases  :  Causesburns (R34)
 SafetyPhrases  :

In case of contact with eyes, rinse immediately with plenty of water and seek medical advice(S26)
Wear suitable protective clothing, eye/face protection and gloves(S36/37/39)

In case of accident or if you feel unwell, seek medical advice immediately(show the label where possible)(S45)

 

Text ofRandSphrasecodesusedinthissafetydatasheet:- R22: Harmfulifswallowed;  R35: Causessevereburns.

Theinformationprovidedabout theproduct onthis SafetyDataSheet hasbeencompiledfromknowledge

of theindividualconstituents Thedatagivenhereisbasedoncurrent knowledgeandexperience.

ThisSafetyDataSheet describestheproduct intermsofsafetyrequirementsanddoesnot signify any

warrantywithregardtotheproduct'sproperties .Thedatagivenhereonlyapplieswhenproduct used

forproperapplication(s). Theproduct isnot sold assuitable forotherapplications-usage in such

may cause risks not  mentioned inthissheet. Donot useforother application(s)without seekingadvicefrommanufacturer

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.


 

top