Corrosion Inhibitor Zinc Based

Corrosion Inhibitor with Zinc salts and Polyphosphates

SKU: RXSOL-40-4029-030 Category:

Description

RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System. Phosphates and zinc stabilizer for anti-scale / anti-corrosion water treatment formulations. Also demonstrates excellent efficiency in the presence of soluble iron where acrylic polymers fail. Excellent dispersant for iron oxides.

Corrosion Inhibitor Zinc Based is a high-performance multi-component corrosion inhibitor system based on zinc chloride and phosphonic acid chemistry. The product provides dual-mode protection through anodic passivation and phosphonate adsorption film formation, offering effective corrosion control in aqueous industrial systems.

 

It is designed for use in closed loop cooling systems, industrial water circuits, hydrostatic testing fluids, and process water systems where both corrosion and mild scaling tendencies are present.

SCALE & CORROSION INHIBITOR FOR HIGH STRESS COOLING WATER SYSTEM…






Product Details

Application

Corrosion Inhibitor OPEN Cooling System  scientifically formulated to keep clean open recirculating systems  and also prevent from scale formation . Chemically Corrosion Inhibitor OPEN Cooling System  will disperse scale and corrosive products, silt etc and can be used as an anti-foulant along with other treatments. 

Excellent scale inhibition for a variety of applications including cooling circuits, boilers and RO units.

It is widely used in Boilers, cooling water and membranes

Where can RXSOL Corrosion Inhibitor Zinc Based be used?

  • Closed loop cooling water systems
  • Industrial heat exchangers and chillers
  • Hydrostatic testing of pipelines and vessels
  • Temporary rust protection of metal surfaces
  • Process water systems in chemical and petrochemical plants
  • Equipment storage preservation fluids

Dosage & Procedure

RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System  is highly concentrated cooling water treatment product, Its small dosage from 0.5 – 1 liter per 10 Tons of Cooling Water. The source of water also directly affecting its dosage as  The dosage depends on the quality of the supply water ( Total hardness and Chloride content as low as possible) .  Control is by simple colourismetric test. 

Optimum result of COOLING SYSTEM can be obtained by maintaing pH level 8 to 8.5 and Total phosphate level should be maintained between 20 and 30 ppm. 

Feel free to ask for RXSOL PHOSPHATE TEST KIT, RXSOL HARDNESS TEST KIT, RXSOL CHLORIDE TEST KIT. We are keeping full range of TEST KIT.

 

DOSAGE BASED ON ZINC LEVELS

ACTIVE ZINC value in system after dosing should be maintained at 1 to 5 ppm.

Therefore, total product dosage must be in the range of 20-80 ppm to prevent scaling and corrosion

Correct dosage can be understood taking into account water quality and other factors.

Rapid protection against corrosion is achieved by pre-treating the system with between three and five times the normal maintenance dosage for seven to ten days. The maintenance dosage is then applied to the recirculating water at all times.

Technical Specifications

PHYSICAL CHARACTERICS 
Appearance   : Clear Liquid - Also available in PINK colour
Specific Gravity  : 1.10 to 1.20
Flash Point  : Non Flammable 
Freezing Point  : 0 Degrees Cent. 
 
Property Specification
Appearance Clear to light amber liquid
Odour Mild acidic
pH (as supplied) 3.0 - 5.5
Specific Gravity (25°C) 1.25 - 1.45
Solubility Completely miscible in water
Flash Point Non-flammable
Stability Stable under normal storage conditions

Notes & Precautions

RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System  compatible with nylon, neoprene or rubber jointings.  


RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System  is a combined dispersant and anti-foulant and corrosion inhibitor which is specially formulated for the prevention of scale, deposits and corrosion in open fresh water, cooling systems. 
 
It is formulated from Polyphosphates, organophosphates and Polyacrylates. 
 
Why is it better to use RXSOL Corrosion Inhibitor Zinc Based?
  • Dual mechanism corrosion protection (inorganic + organic film formation)
  • Rapid formation of protective zinc passivation layer
  • Strong adsorption on steel and alloy surfaces via phosphonate groups
  • Provides scale inhibition (calcium carbonate control)
  • Effective in low to moderate hardness water systems
  • Compatible with common industrial water treatment programs
  • Suitable for short-term and long-term corrosion protection
  • Works in both static and circulating systems

Active Matter

54-63

Generic / Chemical Name

Zinc Based Corrosion Inhibitor

Supply Locations

RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System  Liquid manufacturer and supplier in Mumbai, Turbhe Pawana MIDC, Gandhidham, Visakhapatnam, Chennai Ennore, Kolkata, Haldia, Ajman, Fujairah, Dubai, Sharjah, Dubai, Muscat, Oman, Sohar, Barka, Canada, SUDAN, Yemen

Safety Data (MSDS)

Product Name : RXSOL-40-4029-030
Product Type : Corrosion Inhibitor Zinc Based
Revised Date : 10-04-2022

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
STOCK Point : Fujairah, Mumbai, Kandla, Kolkata, Chennai, Visakhapatnam, Muscat, Nairobi

Phone : +91 22 27815541 / 42
Fax : +91 22 2781 1318 :::AOH :0091 9821214367
Email : mail@rxmarine.com

Chemica Name Concentration CAS Number
Polyphosphates 10-30 10361-03-2
Organophosphates 1-5 115-26-4
Polyacrylates 2-5 9003-04-7
Zinc Sulphate 10-30 7446-19-7
Proprietory Blend 30-60 -------------

*See Section 16

Odour Odourless
Appearance Clear Liquid
Contact with eyes May cause pain
Contact with skin In cases of severe exposure, severe irritation may develop
Inhalation Vapours or aerosols may cause irritation of eyes, nose and respiratory tract
Ingestion Toxic if swallowed (R25)

Contact with skin Remove contaminated clothing immediately and drench affected skin with plenty of water
Contaminated clothing should be laundered before reuse When in doubt or symptoms persist, seek medical attention
Contact with eyes If substance has got into eyes, immediately wash out with plenty of water for at least 15 minutes
Irrigate eyes thoroughly whilst lifting eyelids Obtain immediate medical attention
Ingestion Never make an unconscious person vomit or drink fluids Give water or milk to drink Induce vomiting (only if patient is conscious) Obtain immediate medical attention
Inhalation Inhalation is unlikely to occur Remove patient to fresh air When in doubt or symptoms persist, seek medical attention
General In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible)

-  Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions
-  Substance evolves toxic fumes, wear self-contained breathing apparatus

Personal Precautions Wear protective clothing as per section 8
Immediate Actions Use appropriate containment to avoid environmental contamination (S57)
Clean Up Actions Absorb spillage in inert material and shovel up Ventilate the area and wash spill site after material pick-up is complete.
Special Precautions Wear protective clothing as per section 8

Handling

Wear protective clothing as per section 8 Avoid contact with skin and eyes (S24/25) Eyewash bottles should be available

Storage Keep only in the original container in a cool, well ventilated place (S3/9/49)
Protect from heat

Exposure controls No special precautions are required for this product
Occupational exposure controls Wear suitable protective clothing, including eye/face protection and gloves (plastic or rubber are recommended)

gloves                     goggles                  suit                   

Gloves                          Goggles                        suit                    No_Smoking

Odour Odourless
Appearance Clear to Yellow Liquid
pH 2.0 - 3.8
Boiling point not known
Vapour pressure not known
Vapour density not applicable
Freezing point not known
Completely soluble in water
Specific gravity (water=1) 1.1 - 1.25

-   This article is considered stable under normal conditions
-   Avoid contact with acid
-   Incompatible with acid, Contact with acids liberates toxic gas (R31)
-    See Section 5

Toxicological information No experimental data available
Inhalation Not applicable
Contact with skin In cases of severe exposure, severe irritation may develop
Contact with eyes May cause severe irritation
May cause pain
Ingestion Toxic if swallowed (R25)
Carcinogenicity No evidence of carcinogenic effects

Mobility Completely soluble in water
Persistence and Biodegradability Its main ingredients will either dissolve rapidly and dissociate in water or are readily/inherently biodegradable.
Bioaccumulation Potential Bioaccumulation of the components in this product is insignificant.
Other Adverse Effects No environmental problems are expected when the product is used / handled correctly. In its intended use, the product will not be released into the environment.

Disposal considerations Do not discharge into drains or the environment, dispose to an authorised waste collection point Disposal should be in accordance with local, state or national legislation

 -  Not classified as hazardous for transport

Classification and labeling

Contains Benzothiazol-2-thiol.  May produce an allergic reaction.Cooling Water Treatment 15 Regulatory information

Risk Phrases Toxic if swallowed (R25)
Safety Phrases Wear suitable protective clothing, eye/face protection and gloves (S36/37/39)
In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) (S45) This material and its container must be disposed of in a safe way (S35)

Text of R and S phrase codes used  in  this safety data sheet:-  R25: Toxic I f swallowed;  R43: May  cause  sensitisation by  skin  contact;   The  information  provided  about  the product  on  this  Safety  Data  Sheet  has  been  compiled  from knowledge of the individual constituents.The data given here  is  based  on current knowledge and experience. This Safety Data Sheet describes the product.In terms of safetyr equirements   and   does   not   signify  any   warranty   with  regard  to  the  product's  properties  The  data  given  here  only  applies  when  product  used for proper application(s). The product  is  not  sold  as  suitable for  other applications  -   usage   in  such  may  cause  risks  not   mentioned   in   this  sheet.  Do  not  use  for  other application (s) without seeking advice from manufacturer.

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

top