Home / Product / Drilling Fluids & Mud Oil Field chemicals / Silica Sand AFS 20/25
Silica Sand chemically inert and relatively hard mineral making it ideal for use as filtration media and Sand Blasting
Silica sand is commonly used as a mineral abrasive for industrial blasting. Though blasting with silica sand can create dangerous dust, exposure is easily avoided by following recommended PPE (personal protective equipment) guidelines and/or by coating the sand with solutions designed to control dust.
Silica quartz is often white or colourless, it can come in a wide range of shades. The colour of each sand deposit depends largely on the variety of minerals and rock detritus that make up the resource.
Silica Sand manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Silica Sand at a competitive price from us. We have ready stock of Silica Sand in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

| Product Name | Silica Sand AFS 20/25 |
| Product Type | RXSOL-81-8119-2000 |
Company Details:
RXSOL CHEMO PHARMA INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
STOCK POINT : MUMBAI, Kandla, Chennai, Vizag, Kolkata, Fujairah
| Phone | +91 22 65113333 / 5555 / 9999 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| mail@rxmarine.com |

| Name | CAS# | % by Weight |
| Crystalline Silica (quartz) | 14808-60-7 | 99.0 – 99.9 |
| Aluminum Oxide | 1344-28-1 | <1.0 |
| Iron Oxide | 1309-37-1 | <0.1 |
| Titanium Oxide | 13463-67-7 | <0.1 |

| Inhalation: |
:- Silicosis: The prolonged repeated inhalation of respirable crystalline silica can cause silicosis, a fibrosis (scarring) of the lungs. Silicosis may be progressive; it may lead to disability and death. :- Lung Cancer: Crystalline silica is classified as carcinogenic to humans. :- Tuberculosis: Silicosis increases the risk of tuberculosis. :- Autoimmune and Chronic Kidney Diseases: Some studies show excess numbers of cases of scleroderma, connective tissue disorders, lupus, rheumatoid arthritis, chronic kidney diseases and end-stage kidney disease in workers exposed to respirable crystalline silica. :- Non-Malignant Respiratory Diseases (other than silicosis): Some studies show an increased incidence in chronic bronchitis and emphysema in workers exposed to respirable crystalline silica. |
| Ingestion | Not applicable. |
| Skin contact |
Not applicable. |
| Eye contact: | Crystalline silica (sand or ground silica) may cause abrasion of the cornea. |

|
Eye Contact |
Wash immediately with plenty of water. If irritation persists, seek medical attention. |
|
Skin Contact |
Not applicable |
|
Inhalation |
No specific first-aid is necessary since the adverse health effects associated with inhalation of respirable crystalline silica result from chronic exposures. If there is a gross inhalation of crystalline silica, remove the person immediately to fresh air, give artificial respiration as needed, seek medical attention as needed. |
| Ingestion | Not applicable |

| Extinguishing Media : | Product is not flammable, combustible or explosive. Use extinguishing media appropriate for surrounding fire. |
| Special Fire Fighting Procedures | : Not applicable |

Personal precautions:
Avoid generating dust. If the concentration of respirable silica dust exceeds the OSHA PEL or other applicable limit (if lower than the PEL), wear respirator specified in Section 8 of this Safety Data Sheet.
Environmental precautions:
No specific precautions. Discard any product, residue, disposable container or liner in compliance with regulatory requirements. Methods for
cleaning up: Avoid dry sweeping. Do not use compressed air to clean spilled sand or ground silica. Use water spraying/flushing or ventilated
or HEPA filtered vacuum cleaning system. Dispose of in closed containers.

|
Handling |
Avoid generating dust. Do not breathe dust. Do not rely on your sight to determine if dust is in the air. Respirable crystalline silica dust may be in the air without a visible dust cloud. Use adequate exhaust ventilation and dust collection. Maintain and test ventilation and dust collection equipment. Use all available work practices to control dust exposures, such as water sprays. Practice good housekeeping. Do not permit dust to collect on walls, floors, sills, ledges, machinery, or equipment. Keep airborne dust concentrations below permissible exposure limits. |
| Storage | Use dust collection to trap dust produced during loading and unloading. Keep containers closedand store bags to avoid accidental tearing, breaking, or bursting. |

|
Engineering Controls |
Ventilation must be adequate to maintain the crystalline silica concentrations in the workplace air below the exposure limit(s) outlined in Section 8.3.1 of this Safety Data Sheet. |
| Respiratory Protection |
In case of exposure to dust, and in any case if such exposure is above regulatory limits (see above), wear a personal respirator as outlined in Section 8.2 above. |
| Eye / Face Protection |
If eye contact while using product may be anticipated, wear appropriate safety glasses with side shields or chemical goggles [as described by European Standard EN 166]. |
| Skin Protection | Maintain good industrial hygiene. Protection recommended for workers suffering from dermatitis or sensitive skin. |

| Physical State | White or tan sand: granular, crushed or ground to a powder. |
| Odor | None |
| pH | 6 - 8 |
| Specific Gravity | 2.65 g/cc |
| Melting Point | 3110°F/1710°C |
| Freezing Point | Not Applicable |
| Boiling Point | 4046°F/2230°C |
| Flashpoint | Not Applicable |
| Flammability | Not Applicable |
| Explosive properties | Not Applicable |
| Oxidizing properties | contact with powerful oxidizing agents such as fluorine, chlorine trifluoride, and oxygen difluoride may cause fires. |
| Vapor Pressure | None |
| Relative Density | Not Applicable |
| Solubility | Silica will dissolve in hydrofluoric acid and produce a corrosive gas, silicon tetrafluoride |
| Water Solubility | Insoluble |
| Percent Volatiles by Volume | Not Applicable |
| Viscosity | Not Applicable |

|
Chemical Stability |
Stable |
|
Conditions to Avoid |
Contact with powerful oxidizing agents such as fluorine, chlorine trifluoride, and oxygen difluoride may cause fires. |
|
Materials / Chemicals to Be Avoided |
Contact with powerful oxidizing agents, such as fluorine, chlorine trifluoride and oxygen difluoride, may cause fires. |
|
Hazardous Decomposition Products |
Will not occur |
|
Hazardous Polymerization |
Will not occur |

| Inhalation: |
a. Silicosis: The prolonged repeated inhalation of respirable crystalline silica can cause silicosis, a fibrosis (scarring) of the lungs. Silicosis may be progressive; it may lead to disability and death. b. Lung Cancer: Crystalline silica is classified as carcinogenic to humans. c. Tuberculosis: Silicosis increases the risk of tuberculosis. d. Autoimmune and Chronic Kidney Diseases: Some studies show excess numbers of cases of scleroderma, connective tissue disorders, lupus, rheumatoid arthritis, chronic kidney diseases and end-stage kidney disease in workers exposed to respirable crystalline silica. e. Non-Malignant Respiratory Diseases (other than silicosis): Some studies show an increased incidence in chronic bronchitis and emphysema in workers exposed to respirable crystalline silica. |
| Ingestion | Not applicable. |
| Skin contact |
Not applicable. |
| Eye contact: | Crystalline silica (sand or ground silica) may cause abrasion of the cornea. |

| Ecotoxicological Information | Crystalline silica (quartz) is not known to be ecotoxic; i.e., no data suggests that crystalline silica (quartz) is toxic to birds, fish, invertebrates, microorganisms or plants. |

|
Waste Disposal Method |
Discard any product, residue, disposable container or liner in full compliance with national regulations. |
| Container Handling and Disposal | Dispose of container and unused contents in accordance with national regulations. |

NA

NA

The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and we assume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall ScienceLab.com be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if ScienceLab.com has been advised of the possibility of such damages.
DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.