Gas Turbine Wash F1

Aromatic hydrocarbon solvent cleaner is ideal for heavy duty online and offline gas turbine compressor cleaning.

SKU: RXSOL-36-3602-025 Category:

Description

*]:pointer-events-auto [content-visibility:auto] supports-[content-visibility:auto]:[contain-intrinsic-size:auto_100lvh] R6Vx5W_threadScrollVars scroll-mb-[calc(var(–scroll-root-safe-area-inset-bottom,0px)+var(–thread-response-height))] scroll-mt-[calc(var(–header-height)+min(200px,max(70px,20svh)))]” data-scroll-anchor=”false” data-testid=”conversation-turn-4″ data-turn=”assistant” data-turn-id=”request-WEB:9d187f12-ab02-4402-a299-74684e4ce168-1″ data-turn-id-container=”request-WEB:9d187f12-ab02-4402-a299-74684e4ce168-1″ dir=”auto”>

Compressor cleaning chemical, is developed to deliver maximum cleaning performance, Gas Turbine Wash F1 has become a trusted solution for restoring compressor efficiency and maintaining gas turbine performance under demanding operating conditions.

Gas Turbine Wash F1 is a high-purity blend of hydrocarbon solvents and advanced surfactants engineered for intensive cleaning of gas turbine compressors. It is particularly effective for removing heavy oil contamination, grease deposits, and industrial fouling, making it the preferred choice for severe-duty applications. The product is suitable for both on-line cleaning during turbine operation and off-line cleaning during shutdown maintenance.

The formulation is compatible with all standard on-line and off-line injection systems. For optimal cleaning efficiency and economical chemical consumption, it is recommended to use Gas Turbine Wash F1 with a dedicated Rochem compressor cleaning system specifically designed for the turbine model in use. Rochem offers a comprehensive range of patented manual and fully automatic atomizing injection systems suitable for virtually all gas turbine types.

 
 

 





Product Details

Application

Versatile Application

Gas Turbine Wash F1 is designed for both on-line and off-line compressor cleaning. It can be safely applied while the turbine is operating at any load and speed, allowing maintenance without interrupting production.

Dosage & Procedure

Recommended Dilution

Dilute one part Gas Turbine Wash F1 concentrate with four parts clean water to form a stable cleaning solution suitable for compressor washing.

Technical Specifications

Property Specification
Appearance Clear, colourless liquid
Shelf Life 3 years
Density @ 20°C 0.847 g/mL
Flash Point 88°C
Physical Form Free-flowing liquid
pH (20% in water) 7.4

Notes & Precautions

Key Features and Benefits of Gas Turbine Wash F1

Versatile Application

Gas Turbine Wash F1 is designed for both on-line and off-line compressor cleaning. It can be safely applied while the turbine is operating at any load and speed, allowing maintenance without interrupting production.

Superior Cleaning Performance

The formulation effectively removes a broad spectrum of contaminants commonly encountered in gas turbine compressors, including oil films, dust, hydrocarbons, and industrial deposits. It is widely recognized as the premier product for heavy-duty cleaning applications.

Improved Turbine Efficiency

Routine on-line cleaning with Gas Turbine Wash F1 helps maintain compressor cleanliness, improves power output and heat rate, and minimizes the likelihood of unexpected shutdowns.

Residue-Free Operation

When used according to recommended procedures, Gas Turbine Wash F1 leaves no harmful residues after cleaning, ensuring optimal compressor performance and reducing the risk of secondary fouling.

Proven Safety

The product complies with leading OEM guidelines and has an exceptional safety record, supported by successful use in thousands of gas turbines over millions of operating hours.

Safety Data (MSDS)

Porduct Name               Gas Turbine Wash F1
Part Number   RXSOL-36-3602-210

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Branch : Kandla, Mumbai , Chennai, Vizag, Kolkata, UAE , OMAN , CANADA and KENYA  

Phone +91 22 20871200 - 1400
Fax +91 22 27612100 :::AOH :0091 9821214367
Email mail@rxmarine.com
Website www.rxmraine.com

Product name       Cas No                        EC No              Weight                        
Non ionic surfactants     -        - 10-25 %
Solvent naphtha, heavy arom.  64742-94-5 265-198-5 50-100%
2-(2-butoxyethoxy)ethanol 112-34-5 203-961-6 2.5-10%
Signal Word  Danger
Hazard Statements H304 - May be fatal if swallowed and enters airways.H319 - Causes serious eye irritation. H336 - May cause drowsiness or dizziness.H411 - Toxic to aquatic life with long lasting effects.
Precautionary statements   P261 Avoid breathing dust/fume/gas/mist/vapours/spray.P271 Use only outdoors or in a well-ventilated area. P273 Avoid release to the environment.
Classification of  the substance    or  mixture No data available
Supplemental Hazard    Statements No data available
Other hazards  No data available

General advice First aiders need to protect themselves. Show this material safety data sheet to the doctor in attendance.
If inhaled Supply fresh air; consult doctor in case of complaints.
Eye Contact  Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor
Swallowed If symptoms persist consult doctor.
Skin Contact   Generally the product does not irritate the skin.
Inhalation No data available
Ingestion No data available
Most important  symptoms and effects,  both acute and delaye  The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in section 11
Indication of any immediate medical     attention and special treatment needed  No data available

Flammability                                                  No data available
Suitable extinguishing media  Foam Fire-extinguishing powder Water haze
Unsuitable extinguishing media No data available
Special hazards arising from the substance or mixture  No data available
Further information No data available
Hazardous combustion
products
No data available
Advice for firefighters No data available
Protective Equipment No data available
Specific Hazards Arising from the Chemical No data available

Personal precautions, protective equipment and emergency procedures Ensure adequate ventilation Keep away from ignition sources
Spillage No data available
Personal Protection No data available
Enviromental Precaution Inform respective authorities in case of seepage into water course or sewage system. Dilute with plenty of water. Do not allow to enter sewers/ surface or ground water..
Methods and materials for
containment and  cleaning
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust). Dispose contaminated material as waste according to item 13. Ensure adequate ventilation
Reference to other  sections    For disposal see section 13.

Advice on protection against    fire and    explosion Keep away from open flames, hot surfaces and sources of ignition.
Incompatible materials  No data available
Hygiene measures No data available
Advice on safe handling  Ensure good ventilation/exhaustion at the workplace. Prevent formation of aerosols.
Conditions for safe storage including any  incompatibilities 

No data available

Storage conditions Store away from oxidizing agents.Store in a cool place. Heat will increase pressure and may lead to the receptacle bursting. Keep container tightly sealed.
Storage class No data available
Specific end use(s) Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
Advice on general  occupational  hygiene No data available

Exposure controls  Personal protective equipment 
Engineering Control No data available
Eye/face protection Tightly sealed goggles
Body Protection Solvent resistant gloves Use protective suit
Skin protection Keep away from foodstuffs, beverages and feed. Immediately remove all soiled and contaminated clothing Wash hands before breaks and at the end of work. Avoid contact with the eyes. Avoid contact with the eyes and skin.
Respiratory protection
Not necessary if room is well-ventilated. In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device
Other Protection  Measure No data available

Physical state Fluid
Colour Light yellow
Odour Characteristic
Odor Threshold No data available
pH 7.4
Melting Point < -20°C
Boiling Point 185°C
Flash Point 65°C
Evaporation Rate No data available
Flammability (solid, gas) Chemically unstable at 20 °C temperature and a standard pressure of 101.3 kPa
Explosive limits No data Available
Upper/lower flammability or explosive limits Lower 0.6 Vol % Upper 7.0 Vol %)
Autoignition temperature 225°C
Decomposition temperature  No data available
Vapour pressure 0.9 hPa
Viscosity Dynamic at 20°C: 5 mPas
Density 0.915 g/cm³
Relative Density No data available
Specific Gravity No data available 
Partition coefficient log Pow: -0,3 at 25 °C - Bioaccumulation is not expected.
Explosive properties No data available 
Solubility Dispersible
Ignition temperature No data available
Particle characteristics No data available 

Reactivity                        No data available
Chemical stability No data available
Possibilityof hazardous  reactions No data available
Conditions to  avoid No data available
Incompatible materials
No data available
Hazardous decomposition products In the event of fire: see section 5

Acute toxicity  Alcoholethoxylate Oral LD50 > 2000 mg/kg (rat)
Skin corrosion/irritation No data available
Serious eye      damage/irritation No data available
Respiratory or skin  sensitization  No data available
Carcinogenicity No data available
Germ cell        mutagenicity  No data available
Reproductive toxicity  No data available
Specific target  organ  toxicity - single exposure  
No data available
Additional Information Inhalation of concentrated vapours as well as oral intake will lead to anaesthesia-like conditions and headache, dizziness, etc. The product shows the following dangers according to the calculation method of the General EU Classification Guidelines for Preparations as issued in the latest version: Irritant

Persistence and      degradability Easily biodegradable
Toxicity to fish  No data available
Toxicity to daphnia and other  aquatic invertebrates No data available
Toxicity No data available
Toxicity to bacteria   No data available
Toxicity to algae No data available
Bioaccumulation  potential No data available
Mobility in soil No data availalble
Results of PBT and vPvB  assessment No data available
Endocrine disrupting properties  No data available
Other adverse effects No data availalble
General Note The surfactant(s) contained in this preparation complies(comply) with the biodegradability criteria as laid down in Regulation (EC) No.648/2004 on detergents. Data to support this assertion are held at the disposal of the competent authorities of the Member States and will be made available to them at their direct request. Do not allow product to reach ground water, water course or sewage system. Danger to drinking water if even small quantities leak into the ground. Also poisonous for fish and plankton in water bodies. Toxic for aquatic organisms

Recommondation Must not be disposed together with household garbage. Do not allow product to reach sewage system.
Waste catlogue 15 01 04 metallic packaging 15 01 10 packaging containing residues of or contaminated by dangerous substances
Unclean Pakaging  Packaging may be reused or recycled after cleaning
Recommended cleanising agent Water, if necessary together with cleansing agents

UN number ADR/RID:3082 IMDG:3082

IATA:3082

UN proper  shipping  name  ADR/RID:ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. (Solvent naphta, Contains Alkyl(C3-C5) benzenes, 1,2,4-trimethylbenzene) IMDG:ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. (Solvent naphta, Contains Alkyl(C3-C5) benzenes, 1,2,4-trimethylbenzene) IATA:ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. (Solvent naphta, Contains Alkyl(C3-C5) benzenes, 1,2,4-trimethylbenzene)
Transport hazard  class(es)               ADR/RID:9 IMDG:9      IATA:9
Packaging group ADR/RID:lll                      IMDG:lll IATA:lll
Environmental hazards ADR/RID:No                                    IMDG:No                                IATA:No
Special precautions for  user    No data available                                 
Further information No data available    

Safety, health and environmental    regulations/legislation specific for   the  substance or   mixture The product has been classified and marked in accordance with EU Directives / Ordinance on Hazardous Materials
Other regulations Observe work restrictions regarding maternity protection in accordance to Dir 92/85/EEC or stricter national regulations where applicable. Take note of Dir 94/33/EC on the protection of young people at work
Chemical Safety Assessment A Chemical Safety Assessment has been carried out for this substance.

Other Information

The information above is believed to be accurate and represents the  best information   currently    available  to us.  However,   we   make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and  weassume  no liability resulting from its use. Users should make  their  own  investigations  to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if Rx Marine International  has been advised of the possibility of such damages.

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

top